Project  : Sour water treatment Service
Owner  : PT. Pertamina RU III Plaju
Location  : Palembang, Indonesia
Treatment Capacity  : 5 m3/day

Description

Plasma treatment to treat Sour Water from Oil & Gas Refinary

Parameter that must be achieved:

Comply with Indonesia DOE regulatory limits
BOD, COD, Sulfide (as H2S), Phenol, Total Ammonia, pH

Parameter Inlet
Unit of Measurement Waste water ex Boiler Waste water ex CDU group Waste water ex FCCU group
Debit m3/h 4,4 10,9 24,7
BOD5 mg/L 100 300 600
COD Cr mg/L 200 550 1000
Sulfida (as H2S) mg/L 20 1000 1700
Phenol mg/L 1 152 152
Ammonia total mg/L 2 2300 2700
pH 12 9.5 9.5
Table Plugin
Result
Regulatory Limit Waste water ex Boiler Waste water ex CDU group Waste water ex FCCU group
Debit 4,4 10,9 24,7
BOD5 80 20 42 55
COD Cr 160 90 122 96
Sulfida (as H2S) 0.5 0.01 0.2 0.2
Phenol 0.5 0.01 0.4 0.3
Ammonia total 5 1 2 4
pH 6-9 8.4 7.5 7.5